{"product_id":"sen55-air-quality-sensor-pm-voc-nox-humidity-temperature","title":"SEN55 Environmental Air Quality Sensor – PM, VOC, NOx, Humidity \u0026 Temperature","description":"\u003cp\u003eThe SEN55 environmental sensor node combines particle sensing with VOC and NOx index outputs, relative humidity and temperature measurements. It communicates over I²C for integration into air-quality monitors, ventilation controls, filtration projects and embedded prototypes. It requires a host controller and suitable power supply.\u003c\/p\u003e\n\u003ch2\u003eTechnical Details\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eSEN55, Sensirion SEN5x family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticle outputs\u003c\/th\u003e\n\u003ctd\u003ePM1.0, PM2.5, PM4 and PM10 mass concentrations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther outputs\u003c\/th\u003e\n\u003ctd\u003eVOC Index, NOx Index, relative humidity and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eI²C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e5 V nominal; 4.5–5.5 V operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eSix-pin interface; use a matching connector and verify orientation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntegration\u003c\/th\u003e\n\u003ctd\u003eHost software, suitable enclosure airflow and initialization are required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003ePinout and Connection Guide\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePin\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eVDD\u003c\/td\u003e\n\u003ctd\u003eRegulated 5 V supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003ctd\u003eSupply and controller ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eSDA\u003c\/td\u003e\n\u003ctd\u003eController I²C data; use pull-ups compatible with the host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eSCL\u003c\/td\u003e\n\u003ctd\u003eController I²C clock; use pull-ups compatible with the host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eSEL\u003c\/td\u003e\n\u003ctd\u003eConnect to ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eLeave unconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUse the connector-view drawing in the datasheet to identify pin 1; wire colours alone are not reliable. Supply the sensor from 5 V and use appropriate I²C signal levels. Keep air inlet and outlet clear, and follow the mechanical design and initialization guidance.\u003c\/p\u003e\n\u003ch2\u003eParameters Shown in the Example Dashboard\u003c\/h2\u003e\n\u003cp\u003eThe following values are transcribed from the supplied example screenshot. They are not product specifications, calibration results, guaranteed readings or evidence of testing this stock. Actual readings depend on the environment, firmware and installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eExample value\u003c\/th\u003e\n\u003cth\u003eMeaning \/ qualification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM1.0\u003c\/td\u003e\n\u003ctd\u003e926.0 µg\/m³\u003c\/td\u003e\n\u003ctd\u003eParticle mass concentration for the PM1.0 fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM2.5\u003c\/td\u003e\n\u003ctd\u003e971.1 µg\/m³\u003c\/td\u003e\n\u003ctd\u003eParticle mass concentration for the PM2.5 fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM4\u003c\/td\u003e\n\u003ctd\u003e971.1 µg\/m³\u003c\/td\u003e\n\u003ctd\u003eParticle mass concentration for the PM4 fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM10\u003c\/td\u003e\n\u003ctd\u003e971.1 µg\/m³\u003c\/td\u003e\n\u003ctd\u003eParticle mass concentration for the PM10 fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e8.53 °C\u003c\/td\u003e\n\u003ctd\u003eTemperature reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e52.7 %RH\u003c\/td\u003e\n\u003ctd\u003eRelative humidity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOC Index\u003c\/td\u003e\n\u003ctd\u003e190.21\u003c\/td\u003e\n\u003ctd\u003eDimensionless air-quality index; not a ppm concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOx Index\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003ctd\u003eDimensionless index. The screenshot's “ppm” label is incorrect for the SEN55 NOx output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Fields in the Screenshot\u003c\/h3\u003e\n\u003cp\u003eThese fields are displayed by the example host software. Particle number concentration and typical particle size are not established as standard SEN55 readout fields by the documentation linked here; confirm their source and firmware support before relying on them.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDashboard label\u003c\/th\u003e\n\u003cth\u003eExample value\u003c\/th\u003e\n\u003cth\u003eInterpretation\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC0.5\u003c\/td\u003e\n\u003ctd\u003e6289.2 #\/cm³\u003c\/td\u003e\n\u003ctd\u003eHost-displayed particle number concentration field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC1.0\u003c\/td\u003e\n\u003ctd\u003e6553.4 #\/cm³\u003c\/td\u003e\n\u003ctd\u003eHost-displayed particle number concentration field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC2.5\u003c\/td\u003e\n\u003ctd\u003e6553.4 #\/cm³\u003c\/td\u003e\n\u003ctd\u003eHost-displayed particle number concentration field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC4.0\u003c\/td\u003e\n\u003ctd\u003e6553.4 #\/cm³\u003c\/td\u003e\n\u003ctd\u003eHost-displayed particle number concentration field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC10\u003c\/td\u003e\n\u003ctd\u003e6553.4 #\/cm³\u003c\/td\u003e\n\u003ctd\u003eHost-displayed particle number concentration field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTPS\u003c\/td\u003e\n\u003ctd\u003e0.3 µm\u003c\/td\u003e\n\u003ctd\u003eTypical particle size label in host software; source requires verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi signal strength\u003c\/td\u003e\n\u003ctd\u003e−65 dBm\u003c\/td\u003e\n\u003ctd\u003eHost controller's wireless connection, not a SEN55 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi signal quality\u003c\/td\u003e\n\u003ctd\u003e70%\u003c\/td\u003e\n\u003ctd\u003eHost-derived connection indicator; SEN55 itself communicates over I²C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eWhat the Measurements Mean\u003c\/h2\u003e\u003cp\u003eVOC and NOx outputs are indices for tracking changes in air quality, not compound-specific ppm measurements. SEN55 does not provide CO₂ measurements. Allow the gas-sensing algorithms to initialize and adapt before interpreting results. A finished monitor's performance depends on installation, airflow, compensation settings and software.\u003c\/p\u003e\n\u003ch2\u003eOfficial Datasheet and Hardware Guidance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/sensirion.com\/media\/documents\/6791EFA0\/62A1F68F\/Sensirion_Datasheet_Environmental_Node_SEN5x.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSensirion SEN5x datasheet PDF\u003c\/a\u003e — specifications, pin assignment, connector drawing and I²C commands\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d.sensirion.com\/product-support\/sen5x-environmental-sensor-node\" target=\"_blank\" rel=\"noopener\"\u003eSensirion SEN5x integration and software resources\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\u003cp\u003eOne SEN55 sensor unit. A connection cable appears in the product photos; confirm cable inclusion for the current batch if essential. Controller, display, enclosure and power supply are separate.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does the SEN55 measure?\u003c\/h3\u003e\u003cp\u003eIt reports particle mass concentrations, VOC and NOx indices, humidity and temperature.\u003c\/p\u003e\n\u003ch3\u003eDoes it measure CO₂?\u003c\/h3\u003e\u003cp\u003eNo. Use a separate CO₂ sensor for that measurement.\u003c\/p\u003e\n\u003ch3\u003eAre VOC and NOx outputs in ppm?\u003c\/h3\u003e\u003cp\u003eNo. They are algorithm-generated air-quality indices, not direct ppm concentrations of specific gases.\u003c\/p\u003e\n\u003ch3\u003eCan I use it with Arduino or ESP32?\u003c\/h3\u003e\u003cp\u003eYes, with a compatible I²C driver, correct signal levels and a suitable 5 V supply.\u003c\/p\u003e\n\u003ch3\u003eCan I power it from 3.3 V?\u003c\/h3\u003e\u003cp\u003eNo. Its specified supply range is 4.5–5.5 V. I²C logic compatibility does not change its supply requirement.\u003c\/p\u003e\n\u003ch3\u003eDoes it need an external fan?\u003c\/h3\u003e\u003cp\u003eThe sensor has its own airflow system. Keep its inlet and outlet unobstructed and follow Sensirion's installation guidance.\u003c\/p\u003e\n\u003ch3\u003eHow is it different from SPS30?\u003c\/h3\u003e\u003cp\u003eSPS30 focuses on particulate sensing. SEN55 additionally reports VOC\/NOx indices, humidity and temperature.\u003c\/p\u003e\n\u003ch3\u003eIs this a complete standalone monitor?\u003c\/h3\u003e\u003cp\u003eNo. Add a controller, software, power and any display or enclosure needed for your project.\u003c\/p\u003e\n\u003ch2\u003eRelated Air Quality Sensors\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sps30-pm25-particulate-matter-air-quality-sensor\"\u003eSPS30 particulate matter sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pm2-5-air-quality-sensor-module-pms5003\"\u003ePMS5003 laser particle sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pms7003-dust-laser-sensor-module-embeded-studio\"\u003ePMS7003 laser dust sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/bme680\"\u003eBME680 environmental sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mh-z19c\"\u003eMH-Z19C NDIR CO₂ sensor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCompare measured parameters, wiring, voltage and software before substituting or combining modules.\u003c\/p\u003e","brand":"Embeded Studio","offers":[{"title":"Default Title","offer_id":63044752998770,"sku":"ES-SEN55-AIR-QUALITY","price":12500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/7935\/3202\/files\/SEN55SENSOR.webp?v=1795290721","url":"https:\/\/embededstudio.com\/products\/sen55-air-quality-sensor-pm-voc-nox-humidity-temperature","provider":"Embeded Studio","version":"1.0","type":"link"}